// Copyright 2022 The Prometheus Authors // Licensed under the Apache License, Version 2.0 (the "License"); // you may not use this file except in compliance with the License. // You may obtain a copy of the License at // // http://www.apache.org/licenses/LICENSE-2.0 // // Unless required by applicable law or agreed to in writing, software // distributed under the License is distributed on an "AS IS" BASIS, // WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. // See the License for the specific language governing permissions and // limitations under the License. package main import ( "fmt" "strings" "github.com/go-kit/log" "github.com/go-kit/log/level" "github.com/prometheus/client_golang/prometheus" "github.com/tidwall/gjson" ) // SMARTDevice - short info about device type SMARTDevice struct { device string serial string family string model string } // SMARTctl object type SMARTctl struct { ch chan<- prometheus.Metric json gjson.Result logger log.Logger device SMARTDevice } // NewSMARTctl is smartctl constructor func NewSMARTctl(logger log.Logger, json gjson.Result, ch chan<- prometheus.Metric) SMARTctl { return SMARTctl{ ch: ch, json: json, logger: logger, device: SMARTDevice{ device: strings.TrimPrefix(strings.TrimSpace(json.Get("device.name").String()), "/dev/"), serial: strings.TrimSpace(json.Get("serial_number").String()), family: strings.TrimSpace(json.Get("model_family").String()), model: strings.TrimSpace(json.Get("model_name").String()), }, } } // Collect metrics func (smart *SMARTctl) Collect() { level.Debug(smart.logger).Log("msg", "Collecting metrics from", "device", smart.device.device, "family", smart.device.family, "model", smart.device.model) smart.mineExitStatus() smart.mineDevice() smart.mineCapacity() smart.mineInterfaceSpeed() smart.mineDeviceAttribute() smart.minePowerOnSeconds() smart.mineRotationRate() smart.mineTemperatures() smart.minePowerCycleCount() smart.mineDeviceSCTStatus() smart.mineDeviceStatistics() smart.mineDeviceStatus() smart.mineDeviceErrorLog() smart.mineDeviceSelfTestLog() smart.mineDeviceERC() smart.minePercentageUsed() smart.mineAvailableSpare() smart.mineAvailableSpareThreshold() smart.mineCriticalWarning() smart.mineMediaErrors() smart.mineNumErrLogEntries() smart.mineBytesRead() smart.mineBytesWritten() smart.mineSmartStatus() smart.mineSCSIGrownDefectList() smart.mineSCSIErrorCounterLog() } func (smart *SMARTctl) mineExitStatus() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceExitStatus, prometheus.GaugeValue, smart.json.Get("smartctl.exit_status").Float(), smart.device.device, ) } func (smart *SMARTctl) mineDevice() { device := smart.json.Get("device") smart.ch <- prometheus.MustNewConstMetric( metricDeviceModel, prometheus.GaugeValue, 1, smart.device.device, device.Get("type").String(), device.Get("protocol").String(), smart.device.family, smart.device.model, smart.device.serial, GetStringIfExists(smart.json, "ata_additional_product_id", "unknown"), smart.json.Get("firmware_version").String(), smart.json.Get("ata_version.string").String(), smart.json.Get("sata_version.string").String(), smart.json.Get("form_factor.name").String(), ) } func (smart *SMARTctl) mineCapacity() { capacity := smart.json.Get("user_capacity") smart.ch <- prometheus.MustNewConstMetric( metricDeviceCapacityBlocks, prometheus.GaugeValue, capacity.Get("blocks").Float(), smart.device.device, ) smart.ch <- prometheus.MustNewConstMetric( metricDeviceCapacityBytes, prometheus.GaugeValue, capacity.Get("bytes").Float(), smart.device.device, ) for _, blockType := range []string{"logical", "physical"} { smart.ch <- prometheus.MustNewConstMetric( metricDeviceBlockSize, prometheus.GaugeValue, smart.json.Get(fmt.Sprintf("%s_block_size", blockType)).Float(), smart.device.device, blockType, ) } } func (smart *SMARTctl) mineInterfaceSpeed() { iSpeed := smart.json.Get("interface_speed") for _, speedType := range []string{"max", "current"} { tSpeed := iSpeed.Get(speedType) smart.ch <- prometheus.MustNewConstMetric( metricDeviceInterfaceSpeed, prometheus.GaugeValue, tSpeed.Get("units_per_second").Float()*tSpeed.Get("bits_per_unit").Float(), smart.device.device, speedType, ) } } func (smart *SMARTctl) mineDeviceAttribute() { for _, attribute := range smart.json.Get("ata_smart_attributes.table").Array() { name := strings.TrimSpace(attribute.Get("name").String()) flagsShort := strings.TrimSpace(attribute.Get("flags.string").String()) flagsLong := smart.mineLongFlags(attribute.Get("flags"), []string{ "prefailure", "updated_online", "performance", "error_rate", "event_count", "auto_keep", }) id := attribute.Get("id").String() for key, path := range map[string]string{ "value": "value", "worst": "worst", "thresh": "thresh", "raw": "raw.value", } { smart.ch <- prometheus.MustNewConstMetric( metricDeviceAttribute, prometheus.GaugeValue, attribute.Get(path).Float(), smart.device.device, name, flagsShort, flagsLong, key, id, ) } } } func (smart *SMARTctl) minePowerOnSeconds() { pot := smart.json.Get("power_on_time") smart.ch <- prometheus.MustNewConstMetric( metricDevicePowerOnSeconds, prometheus.CounterValue, GetFloatIfExists(pot, "hours", 0)*60*60+GetFloatIfExists(pot, "minutes", 0)*60, smart.device.device, ) } func (smart *SMARTctl) mineRotationRate() { rRate := GetFloatIfExists(smart.json, "rotation_rate", 0) if rRate > 0 { smart.ch <- prometheus.MustNewConstMetric( metricDeviceRotationRate, prometheus.GaugeValue, rRate, smart.device.device, ) } } func (smart *SMARTctl) mineTemperatures() { temperatures := smart.json.Get("temperature") if temperatures.Exists() { temperatures.ForEach(func(key, value gjson.Result) bool { smart.ch <- prometheus.MustNewConstMetric( metricDeviceTemperature, prometheus.GaugeValue, value.Float(), smart.device.device, key.String(), ) return true }) } } func (smart *SMARTctl) minePowerCycleCount() { smart.ch <- prometheus.MustNewConstMetric( metricDevicePowerCycleCount, prometheus.CounterValue, smart.json.Get("power_cycle_count").Float(), smart.device.device, ) } func (smart *SMARTctl) mineDeviceSCTStatus() { status := smart.json.Get("ata_sct_status") if status.Exists() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceState, prometheus.GaugeValue, status.Get("device_state").Float(), smart.device.device, ) } } func (smart *SMARTctl) minePercentageUsed() { smart.ch <- prometheus.MustNewConstMetric( metricDevicePercentageUsed, prometheus.CounterValue, smart.json.Get("nvme_smart_health_information_log.percentage_used").Float(), smart.device.device, ) } func (smart *SMARTctl) mineAvailableSpare() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceAvailableSpare, prometheus.CounterValue, smart.json.Get("nvme_smart_health_information_log.available_spare").Float(), smart.device.device, ) } func (smart *SMARTctl) mineAvailableSpareThreshold() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceAvailableSpareThreshold, prometheus.CounterValue, smart.json.Get("nvme_smart_health_information_log.available_spare_threshold").Float(), smart.device.device, ) } func (smart *SMARTctl) mineCriticalWarning() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceCriticalWarning, prometheus.CounterValue, smart.json.Get("nvme_smart_health_information_log.critical_warning").Float(), smart.device.device, ) } func (smart *SMARTctl) mineMediaErrors() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceMediaErrors, prometheus.CounterValue, smart.json.Get("nvme_smart_health_information_log.media_errors").Float(), smart.device.device, ) } func (smart *SMARTctl) mineNumErrLogEntries() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceNumErrLogEntries, prometheus.CounterValue, smart.json.Get("nvme_smart_health_information_log.num_err_log_entries").Float(), smart.device.device, ) } func (smart *SMARTctl) mineBytesRead() { blockSize := smart.json.Get("logical_block_size").Float() * 1024 smart.ch <- prometheus.MustNewConstMetric( metricDeviceBytesRead, prometheus.CounterValue, smart.json.Get("nvme_smart_health_information_log.data_units_read").Float()*blockSize, smart.device.device, ) } func (smart *SMARTctl) mineBytesWritten() { blockSize := smart.json.Get("logical_block_size").Float() * 1024 smart.ch <- prometheus.MustNewConstMetric( metricDeviceBytesWritten, prometheus.CounterValue, smart.json.Get("nvme_smart_health_information_log.data_units_written").Float()*blockSize, smart.device.device, ) } func (smart *SMARTctl) mineSmartStatus() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceSmartStatus, prometheus.GaugeValue, smart.json.Get("smart_status.passed").Float(), smart.device.device, ) } func (smart *SMARTctl) mineDeviceStatistics() { for _, page := range smart.json.Get("ata_device_statistics.pages").Array() { table := strings.TrimSpace(page.Get("name").String()) // skip vendor-specific statistics (they lead to duplicate metric labels on Seagate Exos drives, // see https://github.com/Sheridan/smartctl_exporter/issues/3 for details) if table == "Vendor Specific Statistics" { continue } for _, statistic := range page.Get("table").Array() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceStatistics, prometheus.GaugeValue, statistic.Get("value").Float(), smart.device.device, smart.device.family, smart.device.model, smart.device.serial, table, strings.TrimSpace(statistic.Get("name").String()), strings.TrimSpace(statistic.Get("flags.string").String()), smart.mineLongFlags(statistic.Get("flags"), []string{ "valid", "normalized", "supports_dsn", "monitored_condition_met", }), ) } } for _, statistic := range smart.json.Get("sata_phy_event_counters.table").Array() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceStatistics, prometheus.GaugeValue, statistic.Get("value").Float(), smart.device.device, "SATA PHY Event Counters", strings.TrimSpace(statistic.Get("name").String()), "V---", "valid", ) } } func (smart *SMARTctl) mineLongFlags(json gjson.Result, flags []string) string { var result []string for _, flag := range flags { jFlag := json.Get(flag) if jFlag.Exists() && jFlag.Bool() { result = append(result, flag) } } return strings.Join(result, ",") } func (smart *SMARTctl) mineDeviceStatus() { status := smart.json.Get("smart_status") smart.ch <- prometheus.MustNewConstMetric( metricDeviceStatus, prometheus.GaugeValue, status.Get("passed").Float(), smart.device.device, ) } func (smart *SMARTctl) mineDeviceErrorLog() { for logType, status := range smart.json.Get("ata_smart_error_log").Map() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceErrorLogCount, prometheus.GaugeValue, status.Get("count").Float(), smart.device.device, logType, ) } } func (smart *SMARTctl) mineDeviceSelfTestLog() { for logType, status := range smart.json.Get("ata_smart_self_test_log").Map() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceSelfTestLogCount, prometheus.GaugeValue, status.Get("count").Float(), smart.device.device, logType, ) smart.ch <- prometheus.MustNewConstMetric( metricDeviceSelfTestLogErrorCount, prometheus.GaugeValue, status.Get("error_count_total").Float(), smart.device.device, logType, ) } } func (smart *SMARTctl) mineDeviceERC() { for ercType, status := range smart.json.Get("ata_sct_erc").Map() { smart.ch <- prometheus.MustNewConstMetric( metricDeviceERCSeconds, prometheus.GaugeValue, status.Get("deciseconds").Float()/10.0, smart.device.device, ercType, ) } } func (smart *SMARTctl) mineSCSIGrownDefectList() { scsi_grown_defect_list := smart.json.Get("scsi_grown_defect_list") if scsi_grown_defect_list.Exists() { smart.ch <- prometheus.MustNewConstMetric( metricSCSIGrownDefectList, prometheus.CounterValue, scsi_grown_defect_list.Float(), smart.device.device, smart.device.family, smart.device.model, smart.device.serial, ) } } func (smart *SMARTctl) mineSCSIErrorCounterLog() { SCSIHealth := smart.json.Get("scsi_error_counter_log") if SCSIHealth.Exists() { smart.ch <- prometheus.MustNewConstMetric( metricReadErrorsCorrectedByRereadsRewrites, prometheus.CounterValue, SCSIHealth.Get("read.errors_corrected_by_rereads_rewrites").Float(), smart.device.device, smart.device.family, smart.device.model, smart.device.serial, ) smart.ch <- prometheus.MustNewConstMetric( metricReadTotalUncorrectedErrors, prometheus.CounterValue, SCSIHealth.Get("read.total_uncorrected_errors").Float(), smart.device.device, smart.device.family, smart.device.model, smart.device.serial, ) smart.ch <- prometheus.MustNewConstMetric( metricWriteErrorsCorrectedByRereadsRewrites, prometheus.CounterValue, SCSIHealth.Get("write.errors_corrected_by_rereads_rewrites").Float(), smart.device.device, smart.device.family, smart.device.model, smart.device.serial, ) smart.ch <- prometheus.MustNewConstMetric( metricWriteTotalUncorrectedErrors, prometheus.CounterValue, SCSIHealth.Get("write.total_uncorrected_errors").Float(), smart.device.device, smart.device.family, smart.device.model, smart.device.serial, ) } }