mirror of
https://github.com/prometheus-community/smartctl_exporter.git
synced 2024-11-16 01:33:07 +01:00
fix: correct smartctl_device_bytes_written & smartctl_device_bytes_read for NVMe (#211)
The NVMe specification says that the controller is responsible for
reporting "Data Units Read" & "Data Units Written" converted as needed
for logicial block sizes other than 512-bytes. smartmontools already has
the correct behavior.
What is correct in this case? For now, track what smartmontools does:
take the counter, multiply by 512*1000, report the value.
We should be clear that it means the drive has read/written at most
that many bytes.
This has a few impacts:
- NVME devices will now show these metrics, if they did not before.
- NVME devices with blocksize other than 512-bytes may have previously
reported inflated metrics, but are now corrected (is this worthy of
larger notice in changelogs?)
Reference: 11415ee0b9/smartmontools/nvmeprint.cpp (L394-L397)
Closes: https://github.com/prometheus-community/smartctl_exporter/issues/122
Signed-off-by: Robin H. Johnson <rjohnson@coreweave.com>
This commit is contained in:
parent
d6cd1815eb
commit
ea8a38384b
1 changed files with 33 additions and 10 deletions
43
smartctl.go
43
smartctl.go
|
@ -370,34 +370,57 @@ func (smart *SMARTctl) mineNvmeNumErrLogEntries() {
|
|||
)
|
||||
}
|
||||
|
||||
// https://nvmexpress.org/wp-content/uploads/NVM-Express-NVM-Command-Set-Specification-1.0d-2023.12.28-Ratified.pdf
|
||||
// 4.1.4.2 SMART / Health Information (02h)
|
||||
// The SMART / Health Information log page is as defined in the NVM Express Base Specification. For the
|
||||
// Data Units Read and Data Units Written fields, when the logical block size is a value other than 512 bytes,
|
||||
// the controller shall convert the amount of data read to 512 byte units.
|
||||
|
||||
// https://nvmexpress.org/wp-content/uploads/NVM-Express-Base-Specification-2.0d-2024.01.11-Ratified.pdf
|
||||
// Figure 208: SMART / Health Information Log Page
|
||||
// Bytes 47:32
|
||||
// Data Units Read: Contains the number of 512 byte data units the host has read from the
|
||||
// controller as part of processing a SMART Data Units Read Command; this value does not
|
||||
// include metadata. This value is reported in thousands (i.e., a value of 1 corresponds to 1,000
|
||||
// units of 512 bytes read) and is rounded up (e.g., one indicates that the number of 512 byte
|
||||
// data units read is from 1 to 1,000, three indicates that the number of 512 byte data units read
|
||||
// is from 2,001 to 3,000).
|
||||
//
|
||||
// A value of 0h in this field indicates that the number of SMART Data Units Read is not reported.
|
||||
//
|
||||
// Bytes 63:48
|
||||
//
|
||||
// Data Units Written: Contains the number of 512 byte data units the host has written to the ...
|
||||
// (the same as Data Units Read)
|
||||
|
||||
func (smart *SMARTctl) mineNvmeBytesRead() {
|
||||
blockSize := smart.json.Get("logical_block_size")
|
||||
data_units_read := smart.json.Get("nvme_smart_health_information_log.data_units_read")
|
||||
if !blockSize.Exists() || !data_units_read.Exists() {
|
||||
// 0 => not reported by underlying hardware
|
||||
if !data_units_read.Exists() || data_units_read.Int() == 0 {
|
||||
return
|
||||
}
|
||||
smart.ch <- prometheus.MustNewConstMetric(
|
||||
metricDeviceBytesRead,
|
||||
prometheus.CounterValue,
|
||||
// This value is reported in thousands (i.e., a value of 1 corresponds to 1000 units of 512 bytes written) and is rounded up.
|
||||
// When the LBA size is a value other than 512 bytes, the controller shall convert the amount of data written to 512 byte units.
|
||||
data_units_read.Float()*1000.0*blockSize.Float(),
|
||||
// WARNING: Float64 will lose precision when drives reach ~32EiB read/write
|
||||
// The underlying data_units_written,data_units_read are 128-bit integers
|
||||
data_units_read.Float()*1000.0*512.0,
|
||||
smart.device.device,
|
||||
)
|
||||
}
|
||||
|
||||
func (smart *SMARTctl) mineNvmeBytesWritten() {
|
||||
blockSize := smart.json.Get("logical_block_size")
|
||||
data_units_written := smart.json.Get("nvme_smart_health_information_log.data_units_written")
|
||||
if !blockSize.Exists() || !data_units_written.Exists() {
|
||||
// 0 => not reported by underlying hardware
|
||||
if !data_units_written.Exists() || data_units_written.Int() == 0 {
|
||||
return
|
||||
}
|
||||
smart.ch <- prometheus.MustNewConstMetric(
|
||||
metricDeviceBytesWritten,
|
||||
prometheus.CounterValue,
|
||||
// This value is reported in thousands (i.e., a value of 1 corresponds to 1000 units of 512 bytes written) and is rounded up.
|
||||
// When the LBA size is a value other than 512 bytes, the controller shall convert the amount of data written to 512 byte units.
|
||||
data_units_written.Float()*1000.0*blockSize.Float(),
|
||||
// WARNING: Float64 will lose precision when drives reach ~32EiB read/write
|
||||
// The underlying data_units_written,data_units_read are 128-bit integers
|
||||
data_units_written.Float()*1000.0*512.0,
|
||||
smart.device.device,
|
||||
)
|
||||
}
|
||||
|
|